Leading Manufacturer Of Voltage Stabilizers(AVR) & low-Voltage transformers+8613916759436[email protected]
Power-Frequency Online UPS
  • Power-Frequency Online UPS
  • Power-Frequency Online UPS
  • Power-Frequency Online UPS
  • Power-Frequency Online UPS

Power-Frequency Online UPS

Robust double-conversion UPS with 0 ms transfer time for industrial equipment and centralized power protection

Rated Capacity:6–200 kVA
Phase Configuration:3P/1P and 3P/3P
Input Voltage:380 or 400 V AC ±25% (3P/1P) / 285–480 V AC (3P/3P)
Output Voltage:220 or 230 V AC ±1% (1P) / 380 or 400 V AC ±1% (3P)
Output Frequency:50/60 Hz
Transfer Time:0 ms
Battery Voltage:192–384 V DC, depending on model
Isolation Transformer:Built-in input and output isolation transformers on 3P/1P models

Overview

The Power-Frequency Online UPS series provides regulated backup power through an online double-conversion topology for industrial and infrastructure loads. It covers 6–200 kVA with three-phase input/single-phase output and three-phase input/three-phase output configurations. The three-phase-input/single-phase-output range is documented with built-in input and output isolation transformers, supporting load compatibility and resistance to supply-side disturbance. Across the series, sine-wave output, zero transfer time, electronic short-circuit current limiting, overload handling, LED status indication, and LCD operating data support continuous system supervision. Model-dependent battery voltages and cabinet sizes accommodate different capacity levels and runtime requirements. Typical uses include data rooms, communications facilities, medical equipment, production controls, security systems, and industrial process equipment. Because the two phase configurations differ in voltage, overload duration, battery arrangement, noise, and physical construction, their specifications are presented separately.

Technical Specifications

Three-Phase Input / Single-Phase Output Configuration

Parameter Specification
Model range GP3106KS, GP3110KS, GP3115KS
GP3120KS, GP3130KS, GP3140KS
GP3160KS, GP3180KS
Rated capacity range 6–80 kVA
Input phase configuration Three-phase, five-wire input
Rated input voltage 380 or 400 V AC
Input voltage range Rated input voltage ±25%
Input frequency range 45–65 Hz
Input power factor >0.98
Rated output voltage 220 or 230 V AC
Output voltage accuracy ±1%
Output frequency 50 / 60 Hz
Output frequency accuracy ±0.5 Hz
Output power factor 0.8
Output waveform Sine wave
Transfer time 0 ms
Waveform distortion Linear load: ≤3%; non-linear load: ≤5%
Overload capability 110%: 10 min; 125%: 1 min; 150%: 300 ms
Short-circuit protection Electronic current limiting at 1.3 times rated current
Battery voltage GP3106KS–GP3115KS: 192 V DC; GP3120KS–GP3140KS: 192 V DC, with 192–240 V selectable; GP3160KS–GP3180KS: 384 V DC
LED Input, inverter, bypass, and battery status; UPS fault and overload indication
LCD Input/output voltage, frequency, battery voltage, load percentage, and internal temperature
Operating temperature 0–40 °C
Storage temperature −25–55 °C
Relative humidity 0–95%, non-condensing
Noise <54 dB at 1 m

Three-Phase Input / Three-Phase Output Configuration

Parameter Specification
Model range GP3310KS, GP3315KS, GP3320KS
GP3330KS, GP3340KS, GP3360KS
GP3380KS, GP33100KS, GP33120KS
GP33160KS, GP33200KS
Rated capacity range 10–200 kVA
Input phase configuration Three-phase, five-wire input
Input voltage range 285–480 V AC
Input frequency range 50 / 60 Hz ±5 Hz, automatic detection
Input power factor >0.98
Rated output voltage 380 or 400 V AC
Output voltage accuracy ±1%
Output frequency Automatically tracks input frequency
Output power factor 0.8
Output waveform Sine wave
Transfer time 0 ms
Waveform distortion Linear load: ≤3%; non-linear load: ≤5%
Overload capability 110%: 10 min; 125%: 3 min; 150%: 1 min
Short-circuit protection Electronic current limiting at 1.3 times rated current
Battery voltage 384 V DC; 29 / 30 / 31 / 32 batteries adjustable
LED Input, inverter, bypass, and battery status
LCD Input/output voltage, frequency, battery voltage, load percentage, and internal temperature
Operating temperature 0–40 °C
Storage temperature −25–55 °C
Relative humidity 0–95%, non-condensing
Noise GP3310KS–GP3320KS: <54 dB; GP3330KS–GP3360KS: <60 dB; GP3380KS: <65 dB; GP33100KS–GP33200KS: <70 dB

Models, Dimensions and Weight

Three-Phase Input / Single-Phase Output Models

Model Rated Capacity Input / Output Configuration Dimensions (W × D × H) mm Net Weight kg Gross Weight kg
GP3106KS 6 kVA 3P / 1P 250 × 580 × 720 118 138
GP3110KS 10 kVA 3P / 1P 305 × 600 × 870 200 256
GP3115KS 15 kVA 3P / 1P 305 × 600 × 870 220 265
GP3120KS 20 kVA 3P / 1P 410 × 680 × 920 240 288
GP3130KS 30 kVA 3P / 1P 410 × 680 × 920 269 305
GP3140KS 40 kVA 3P / 1P 730 × 460 × 1200 310 350
GP3160KS 60 kVA 3P / 1P 800 × 730 × 1400 450 510
GP3180KS 80 kVA 3P / 1P 800 × 730 × 1400 500 550

Three-Phase Input / Three-Phase Output Models

Model Rated Capacity Input / Output Configuration Dimensions (W × D × H) mm Net Weight kg Gross Weight kg
GP3310KS 10 kVA 3P / 3P 410 × 670 × 950 130 180
GP3315KS 15 kVA 3P / 3P 410 × 670 × 950 140 190
GP3320KS 20 kVA 3P / 3P 410 × 670 × 950 205 224
GP3330KS 30 kVA 3P / 3P 410 × 670 × 950 230 245
GP3340KS 40 kVA 3P / 3P 450 × 820 × 1060 250 298
GP3360KS 60 kVA 3P / 3P 490 × 850 × 1230 359 416
GP3380KS 80 kVA 3P / 3P 560 × 900 × 1300 400 429
GP33100KS 100 kVA 3P / 3P 560 × 900 × 1300 474 554
GP33120KS 120 kVA 3P / 3P 800 × 1200 × 1700 650 700
GP33160KS 160 kVA 3P / 3P 800 × 1200 × 1700 785 815
GP33200KS 200 kVA 3P / 3P 850 × 1200 × 1800 840 1150

Production & Quality

Production, assembly, inspection and functional testing of UPS systems before delivery.

On-site Installation

UPS installation, battery-system integration and on-site electrical connection for customer projects.

Get a Quick Quote