Leading Manufacturer Of Voltage Stabilizers(AVR) & low-Voltage transformers+8613916759436[email protected]
AC Variable Frequency Power Supply
  • AC Variable Frequency Power Supply
  • AC Variable Frequency Power Supply
  • AC Variable Frequency Power Supply
  • AC Variable Frequency Power Supply
  • AC Variable Frequency Power Supply

AC Variable Frequency Power Supply

IGBT-based AC power supply for 50Hz, 60Hz and 400Hz frequency conversion

Rated Capacity:0.5–1800 kVA
Input Voltage:Configurable for Global AC Systems
Input Frequency:40–79 Hz
Output Voltage:3-Phase 0–520 V / 1-Phase 0–300 V Adjustable
Output Frequency:40–73 Hz Adjustable / 50, 60 & 400 Hz Fixed
Custom configurations: Other input/output voltages, 100/200 Hz fixed output, and customized frequency ranges from 5–1000 Hz are available on request.

AC Static Frequency Converter Power Supply Overview

WVFP series is an AC static frequency converter power supply based on AC-DC-AC power conversion technology. It converts an available AC supply into a stable AC output at the voltage and frequency required by the connected equipment.

WVFP is a static AC power source, not a motor speed controller or a variable frequency drive (VFD). Instead of regulating the speed of a motor, it provides a complete AC power source for connected equipment, with output voltage and output frequency selected to match that equipment.

Output voltage and output frequency are configurable:

  • Output voltage: three-phase up to 520Vac, single-phase up to 300Vac
  • Output frequency: adjustable, with fixed 50Hz / 60Hz / 400Hz settings for dedicated applications

Typical uses include matching different national grid standards, power compatibility for exported equipment, production line and laboratory power testing, and special-frequency applications.

Application Examples: Voltage & Frequency Conversion and Equipment Testing

WVFP provides configurable AC power with adjustable voltage and frequency output for export equipment testing, export equipment power adaptation, and 400Hz aircraft ground power applications.

WVFP-33030KVA 30kVA variable frequency power supply used for export equipment testing.

Export Equipment Testing for Global Grid

WVFP provides adjustable voltage and frequency output for export equipment testing. Installed in a 380V/50Hz industrial power environment, the system can simulate different overseas grid conditions, such as 208V/60Hz, for equipment verification before shipment.

WVFP frequency converters with control panels lit during a factory aging test before delivery.

Export Equipment Power Supply Adaptation

WVFP converts different grid conditions for exported equipment. For PVD vacuum coating equipment shipped to the USA, it adapts 480V/60Hz power supply to 380V/50Hz required for stable operation.

WVFP variable frequency power supply configured for a 400Hz special frequency application.

400Hz Aircraft Ground Power Application

WVFP provides 400Hz AC power output for aircraft ground power applications, supporting aircraft maintenance, ground operation and aviation equipment requirements.

WVFP industrial frequency conversion power system for equipment power supply.

More Frequency Conversion Solutions

Explore more WVFP applications for voltage conversion, frequency conversion and equipment power compatibility.

View Frequency Conversion Solutions

Working principle

WVFP series variable frequency power supply adopts AC-DC-AC conversion technology. The input AC power is converted into DC voltage through rectification, then converted back to a stable AC output through an IGBT inverter system. This architecture enables independent adjustment of output voltage and frequency for different equipment power requirements.

AC-DC-AC Conversion Process

AC Variable Frequency Power Supply

The AC-DC-AC conversion structure consists of rectification, DC bus, IGBT inverter and output filtering stages to provide stable voltage and frequency conversion.

Control System and Protection

The control system integrates voltage, current and protection feedback functions to maintain stable output performance under different operating conditions.

AC Variable Frequency Power Supply

List Of  WVFP Technical Parameters

Input Specifications

Parameter Specification
Rated Voltage(Vac) Three Phase 200V,208V,220V,380V,400V,440V,480V(Any voltage can be customized)Single phase 110V,220V,230V,380V(Any voltage can be customized)
Three phase three wire (L1, L2, L3) + Ground(PE).Single phase two line (L, N) + Ground(PE).The system can use a Neutral line or not.Any line entry method can be customized
Input Voltage Range(%) (Rated Voltage)±15%.e.g.380V±15%(Customizable other voltage input ranges)
Generally, the input voltage range can be ±15%,20%,30%,40% of the rated voltage.
Input Frequency(Hz) Default 40~79Hz
Other frequencies can be customized

Output & Regulation Performance

Parameter Specification
Inverter modulation mode IGBT Drive/SPWM(Sinusoidal Pulse Width Modulation)
Output voltage(Vac) Default:Three phase 0-520V voltage adjustable, Single-phase 0-300V voltage adjustable (Other voltages can be customized e.g.690V,800V,1000V,3000V,3300V…)
Output voltage stability (average accuracy) ±1%(Higher output accuracy can be customized)
Dynamic Response time <2ms(Relative AC input voltage)
Output Voltage Waveform Distortion Rate <2%(Linear load)
Output Frequency 40Hz-73Hz adjustable, 50/60/400Hz fixed (100Hz/200Hz optional, 5-1000Hz customizable)
Frequency Stability <0.1%
Phase offset When the load is three-phase balanced or no-load: ≤±1°; when the load is 100% three-phase unbalanced: ≤±4°
Three-phase imbalance Three-phase voltage automatic control balance

Control & Communication

Parameter Specification
Control Mode Full digital control
The analog part is used for input and output signal conditioning
Main control unit The main chip uses DSP(TI28XX) for control and measurement
Some models use ARM master control with DSP function
Control strategy SPWM(Sinusoidal Pulse Width Modulation)
Switching Frequency 4~16K(According to different power)
Voltage and current measurement methods True RMS sampling (three-phase synchronization)
RMS & FFT sampling 256 points
Voltage & Current & Frequency Control Strategy PID double closed loop control
Communication interface RS485/232/MODBUS-RTU Protocol
Optional TCP/IP, GPRS and other interfaces

Display & Monitoring

Parameter Specification
Display Media Industrial touch screen(7″or 10″)
Other sizes of LCD can also be customized
Display electrical parameters Input three-phase voltage and frequency;
Output three-phase line voltage and frequency;
Output line voltage average value;
Output power factor;Output three-phase current;
Output active power and apparent power;
Heat sink temperature
Display alarm information Input overvoltage (OV), overcurrent (OC); input undervoltage (UV); IGBT failure; heat sink overheat; transformer overheat; and other fault information
Display accuracy The accuracy is Class 0.5s
Voltage display resolution 0.1V
Current display resolution 0.1A

Protection

Parameter Specification
Protection List Input overvoltage (OV), overcurrent (OC); input undervoltage (UV); IGBT failure; heat sink overheat; transformer overheat; and Short Circuit.
Protection Action Cut off output and alarm
Fault dry contacts can be configured(NC&NO)

Other special requirements can be communicated with winzele

Recommended Applications

Export Equipment Testing

Simulating different voltage and frequency conditions for exported equipment verification before shipment.

Industrial Equipment Power Supply

Providing stable AC power with adjustable voltage and frequency for equipment commissioning and operation.

Laboratory Equipment Testing

Supporting voltage and frequency verification for electrical products, components and testing systems.

Aviation Ground Power

Providing 400Hz AC power output for aircraft ground support and aviation equipment applications.

List of  WVFP Power Models & Products

1.Three-phase Model List

Small Capacity (3-30 kVA)

Type Capacity
(kVA)
Output Current(A) Dimension
W×D×H(mm)
High
Volt 
Low
Volt
WVFP13003
WVFP33003
3 4.2 8.4 350×650×670
(Locking Castor Wheel)
WVFP13006
WVFP33006
6 8.4 16.8
WVFP13010
WVFP33010
10 15 30
WVFP13015
WVFP33015
15 23 46 460×700×1170
(Locking Castor Wheel)
WVFP13020
WVFP33020
20 30 60
WVFP33030 30 45 90

Medium Capacity (45-200 kVA)

Type Capacity
(kVA)
Output Current(A) Dimension
W×D×H(mm)
High
Volt 
Low
Volt
WVFP33045 45 68 136 780×650×1450
WVFP33060 60 91 182
WVFP33075 75 114 228 950×700×1600
WVFP33090 90 137 274
WVFP33120 120 183 366
WVFP33150 150 228 456 1200×750×1800
WVFP33200 200 304 608

Large Capacity (250-800 kVA)

Type Capacity
(kVA)
Output Current(A) Dimension
W×D×H(mm)
High
Volt 
Low
Volt
WVFP33250 250 380 760 1400×800×2000
WVFP33300 300 456 912
WVFP33350 350 532 1064 1500×1050×2000
WVFP33400 400 608 1216
WVFP33500 500 760 1520 1500×1050×2000
WVFP33600 600 912 1824
WVFP33800 800 1216 2432

Extra-Large Capacity (1000-1800 kVA)

Type Capacity
(kVA)
Output Current(A) Dimension
W×D×H(mm)
High
Volt 
Low
Volt
WVFP331000 1000 1520 3040 1500×1050×2000
WVFP331200 1200 1823 3646
WVFP331400 1400 2127 4254 1500×1050×2000
WVFP331600 1600 2431 4862
WVFP331800 1800 2735 5470 1500×1050×2000

Notice:

1. For 90kVA and below, use high and low voltage switch. For 90kVA and above, choose one of the high and low voltage when ordering;

2. The current in the table is calculated when the line voltage is 380V. The actual use should be calculated according to the highest voltage of the selected equipment;

2.Single-phase Model List

Small Capacity (0.5-30 kVA)

Type Rated capacity(kVA) Output Current(A) Dimension W×D×H(mm)
High Volt Low Volt
VFP11-500W 0.5 2.1 4.2 425×436×173
WVFP11001 1 4.2 8.4
WVFP11002 2 8.5 17 350×650×670
(Locking Castor Wheel)
WVFP11003 3 13 26
WVFP11005 5 21 42
WVFP11010
WVFP31010
10 42 84
WVFP11015
WVFP31015
15 63 126 460×700×1170
(Locking Castor Wheel)
WVFP11020
WVFP31020
20 84 168
WVFP11030
WVFP31030
30 126 252

Medium Capacity (45-300 kVA)

Type Rated capacity(kVA) Output Current(A) Dimension W×D×H(mm)
High Volt Low Volt
WVFP11045
WVFP31045
45 189 378 780×650×1450
WVFP31060 60 252 504
WVFP31075 75 315 630 950*700*1600
WVFP31090 90 378 756
WVFP31120 120 504 1008 1200×750×1800
WVFP31150 150 630 1260
WVFP31200 200 840 1680 1400×800×2000
WVFP31300 300 1350 2700

Manufacturing & Quality Assurance

WVFP variable frequency power supply electrical testing and functional verification

Electrical Testing & Verification

WVFP units undergo electrical testing and functional verification to ensure stable output performance before delivery.

WVFP variable frequency power supply production line and assembly

Production and Assembly

Multiple WVFP units are assembled and inspected in the production area to support different voltage and frequency conversion requirements.

WVFP variable frequency power supply motor load testing

Motor Load Testing

WVFP systems are tested with motor loads to verify stable AC output performance under industrial operating conditions.

WVFP system assembly with modular power units and control components

System Assembly Capability

WVFP systems are assembled with modular power units and control components for industrial voltage and frequency conversion applications.

WVFP solutions are available for industrial equipment testing, export power compatibility, and special frequency applications.

Get a Quick Quote

Contact our sales team for pricing, technical specifications, and delivery information.

Chat on WhatsApp Email Us