High-Current Dry Transformers
Rated Power: 0.5-1250KVA
Input Voltage: 110/200220/380/440/480V
Input Frequency: 50/60Hz±10%
Output Voltage: 1-60V or other Voltage
MOQ: 1 Set/Piece
Brand: WINZPOWER
Product Introduction
The low-voltage high-current transformer is also an isolation transformer, so it meets the electrical indicators of the SG series isolation transformer; the difference from the general isolation transformer is that the primary voltage is high and the current is small; the secondary voltage is low and the current is large. According to customer needs, taps can be installed on the primary side, and then the secondary voltage and current can be adjusted; please note that the input power needs to be disconnected to operate when replacing the tap. The low-voltage high-current transformer is suitable for use in an environment with a rated frequency of 50/60Hz; if the voltage and current of the load need to be linearly adjusted, a voltage regulator can be installed on the input side of the high-current transformer.
Product functions and features
The core of low-voltage high-current transformer is made of cold rolled oriented high quality silicon steel sheets, and the coil structure adopts cylindrical, elliptical and rectangular cylinders. Low-voltage high-current transformer adopts split or integrated structure according to product volume and weight, and has the characteristics of stepless adjustment of output current, balanced current rise, large load variation range, reliable operation, simple operation and safety. It is an ideal equipment for industrial and mining enterprises to carry out current rise, heating or temperature rise test.
Application
Application:
1. Heating field:
Used in electric furnaces, heating furnaces, aluminum smelting and other equipment, providing large current to meet heating needs, suitable for industrial processes such as mechanical parts heating, heat treatment, powder metallurgy, etc.
2. Test equipment:
In the test of electrical equipment such as current transformers, circuit breakers, contactors, etc., provide large current for temperature rise, protection characteristics and other tests.
3. Electric welders and spot welders:
Provide large current for welding operations, suitable for welding of various metal materials.
4. Electroplating and other industrial applications:
In the electroplating process, provide large current to achieve electroplating of metal surfaces, and can also be used for other industrial production processes that require large current
5. Pipeline preheating
Used for heating tubular hot wall systems in the semiconductor industry, used for the diffusion process of 2-8 inch silicon wafers (semiconductor diffusion furnace sintering furnace)
List Of High-Current Dry TransformersTechnical Parameters
Technical Parameters | ||
No. | Technical Indicators | Content |
1 | Product Model | DG/SG-Series Dry-Type Isolation Transformer |
2 | Rated Capacity (KVA) | 200VA-500KVA |
3 | Input Voltage(VAC) | Three-phase 380V&400V Single-phase 220V 110V ±10% |
4 | Output Voltag(VAC) | 1-60V and other customer specified voltages |
5 | System Maximum Operating Voltage(V) | 530V |
6 | Winding Material | All Copper Wire Wrapped Wire |
7 | Connection Group | DYn11 YYn0 and other customer specified connection groups |
8 | Rated Frequency(Hz) | 50/60Hz |
9 | Rated Phases | 3 Phases |
10 | Cooling Method | Temperature Control Forced Air Cooling |
11 | Insulation Class | H, F, B |
12 | Insulation Level | Power Frequency Withstand Voltage 3KV, No Breakdown and No Flashover |
13 | Overload Capacity | 2 Times Rated Current, Maintain 1 Minute |
14 | Display Function | Input and output voltage and current display, temperature display |
15 | Short-circuit impedance | <3.5% |
16 | No-load loss | According to standard GB1094.11-2007 |
17 | Load loss | According to standard GB1094.11-2007 |
18 | Protection level(IP Class) | IP20 Indoor, IP33 Outdoor can be customized |
19 | Dimensions | See the table below |
20 | Color | RAL7035, other colors can be customized |
21 | Installation location | Indoor |
22 | Relative humidity | 10%~90% RH |
23 | Altitude | Below 3000 meters Capacity derated by 10% for every 1000 meters increase in altitude |
24 | Ambient temperature | -25~+55℃ Maximum daily average temperature: 35℃ |
25 | Earthquake resistance | Ground horizontal acceleration 0.2g, vertical acceleration 0.1g |
26 | Use environment | The installation location is free of severe steam, chemical deposition, dust and explosives, etc. |
27 | Lead-in method | Transformer high and low voltage lead-in method: cable in and out from the bottom |
28 | Installation method | Foot-mounted fixed installation |
29 | Lifting method | Bottom forklift lifting |
30 | Noise | 55db |
31 | Magnetic flux density | Magnetic flux density ≤1.58T |
31 | Implementation standard | GB1094.11-2007 |
Other special requirements can be communicated with winzele |