0-3000V single-phase isolation adjustable transformer 60KVA
Rated Power: 5~300KVA
Input Voltage: 380V/400V/440V±15%
Input frequency:50/60Hz
Output Voltage: 0-3300V
Brand: WINZPOWER
Packaging: Plywood Case
Product Introduction
Isolation transformers are commonly used for long-distance power transmission, especially for underwater probes, AUVs, and ROVs. Because of the long distances and the significant voltage drop after deep diving, high-voltage input is essential. Mothership power supplies only provide 440V or 400V, necessitating the use of an isolation transformer.
Technical Parameters
INPUT | |
Type | Dry |
Power Rating(KVA) | 60KVA |
Voltage Range(VAC) | 400V |
Frequency(Hz) | 50/60Hz |
Phases | 1 Phases (L1+L2) |
Current(A) | 158A |
OUTPUT | |
Power Rating(KVA) | 60KVA |
Current Rating(A) | 20A |
Output Voltage(V) | 0-3000V |
Frequency | 50Hz/60Hz |
Efficiency | 98% |
Safety performance | |
Isolation Resistance | ≥2MΩ |
Withstand voltage | 2500V |
Protection function | |
Water proof | IP44 |
Salt spray protection | * |
Display | |
Display media | Touchscreen 7” |
Voltage |
Input and output voltage, true RMS value calculation LCD display
|
Current | Input Current, true RMS value calculation LCD display |
Other features | |
Communication | RS485 Modbus RTU |
Working Temperature | -35℃+55℃ |
Relative Humidity | 10%-90%(20℃±5℃) |
Altitude | <2000m |
Noise Level(dB) | <55dB |
Feature
1.Distance-following function:
The supply voltage changes with underwater distance. For example, the longer the distance, the higher the output voltage; similarly, the closer the distance, the lower the output voltage.
2.Power-following function:
The supply voltage increases with greater underwater load, and decreases with less underwater load.
3.Fully isolated system
The ship power supply and underwater load power supply are completely isolated through the isolation transformer, effectively filtering out electrical interference
4.Salt spray protection
Transformer encapsulated in epoxy resin to protect against shore moisture.
5.Insulation monitoring function:
When leakage current or short circuit occurs in the wire, an alarm will be prompted and the output power supply will be disconnected.